Read articles →A hands-on diagnostic fix for the well-known A/C freeze-up issue on Massey Ferguson 4700-series tractors, focused entirely on repositioning the evaporator temperature probe. The creator explains why bypassing the probe switch makes things worse, walks through his trial-and-error testing process with pressure gauges and a vent thermometer, and gives a target cycling range of roughly 45-50°F. Most useful to owners already wrestling with this specific problem.
The evaporator temperature probe is not positioned correctly, so it fails to sense cold temperature and cut the compressor off in time, causing the evaporator to freeze.
No, bypassing it is the worst thing you can do. The probe senses temperature and cuts the compressor off when it gets too cold, preventing freeze-up.
The goal is about 45 degrees before the compressor cuts off, then it should come back on around 50 degrees and repeat the cycle.
Run it on setting one or two, not three or four, so the de-icing switch has to work and the evaporator can get as cold as possible.