Pick a make and model. Full spec sheet, tractor videos, and similar tractors on one page.
Find a model →Compare up to four models side by side. Engine, hydraulics, hitch, weight, warranty.
Open comparison →Written guides on choosing tractors, hydraulics, PTO, hitches, and maintenance.
Read articles →This is a real-time troubleshooting session on a 2020 Workmaster 25 that wouldn't start after a frozen fuel filter bowl, not a dealer walkaround. The owner, a professional diesel mechanic, checks fuel flow at the pump, injectors, and the electronic fuel shutoff solenoid, suspecting a stuck solenoid before discovering the actual fix was simply re-priming the system. Useful for owners facing cold-weather crank-no-start issues on this tractor.
The fuel filter bowl froze with water in it. After changing the filter it still would not start because the fuel system had lost its prime, not because of a stuck solenoid.
Check the exhaust for smoke. White smoke means unburnt fuel and not enough cylinder heat. No white smoke means you are getting zero fuel to the tractor.
Turn the key on and let the fuel pump cycle and run for a few minutes to reprime the system, then it will start right up.